AOV and smoke vent servicing and repairs
Automatic opening vents (AOVs) let smoke out of stairwells and corridors during a fire, so people can escape and firefighters can get in. We install, link, test and repair AOV systems in blocks of flats and commercial buildings.
- Stairwells and lobbies in blocks of flats
- Corridors and stair cores in offices and commercial buildings
- Landlords, managing agents and freeholders

What the job involves
An AOV system has four main parts: the vents themselves (opening windows, roof vents or louvres), the actuators (motors) that open and close them, a control panel with a backup battery, and the things that tell it to open, usually smoke detectors in the stairwell or a signal from the main fire alarm. There’s normally a manual control too, often a key switch or a break-glass style box for the fire service, labelled for each floor.
For a new system or an upgrade, we look at the building, how the existing fire alarm works and what the fire strategy or fire risk assessment needs, then fit or replace the control panel, actuators, detectors and manual controls and link them to the fire alarm where needed. For an existing system, we survey what’s there, test it end to end and fix what isn’t working.
Many of the AOV jobs we see are in blocks of flats, where the vents sit at the top of the stairwell or on each landing. Our photo shows the floor-by-floor smoke vent controls above a fire alarm repeater panel on one of our jobs.
Common AOV problems
The faults we see most are vents that won’t open fully or won’t close, worn or burnt-out actuators, flat backup batteries in the control panel, damaged manual call points, and a broken link between the fire alarm and the AOV panel after other building work. Most can be fixed in a single visit once we know what’s wrong.
What you get
- Vents that open when they should and close properly afterwards.
- A tested link between the AOVs and the fire alarm, where there is one.
- Clearly labelled manual controls for the fire service.
- A record of every test, repair and service. We complete your certificate or service report on site and email it to you before the job is closed, and every one is kept in your online portal.
- One contractor for the fire alarm, AOVs, emergency lighting and extinguishers in the building.
How servicing works
On a service visit we operate every vent from the automatic trigger and the manual controls, check that each one opens fully and closes and seals properly, check the actuators and hinges, test the control panel and its backup battery, and confirm the link from the fire alarm still works. We note anything worn or failing and quote for repairs before doing them.
Between services, whoever manages the building should carry out the regular checks set by the fire risk assessment. In high-rise blocks of flats, the Fire Safety (England) Regulations 2022 also require regular checks of key fire safety equipment. If you manage several buildings, see our page for landlords and letting agents: we keep every building’s service dates on file and remind you before they’re due.
AOVs work hand in hand with the fire alarm, so we often service both on the same visit.
Often booked together: fire alarm installation and servicing and emergency lighting testing.
Your paperwork: We complete your certificate or service report on site and email it to you before the job is closed. It has a QR code to check it’s genuine, and it’s always in your online portal.
Areas we cover
We look after AOV systems across our main areas, and further afield for larger jobs:
Full coverage across Hertfordshire, Bedfordshire, Buckinghamshire and Cambridgeshire, plus north and west London, Harlow (Essex) and Windsor (Berkshire).
Commercial projects further afield by arrangement. See all the areas we cover.
Some of our work
Radlett
Peterborough
Shane
Questions people ask
What is an AOV?
An automatic opening vent is a window, roof vent or louvre that opens by itself when smoke is detected, to let smoke out of a stairwell or corridor. Most systems also have a manual control so the fire service can open or close the vents.
How often should AOVs be tested?
They should be tested regularly and serviced by a competent person, commonly at least once a year, with more frequent function checks by whoever manages the building. Your fire risk assessment or the system’s manufacturer will set the exact schedule.
Our vent won’t close after a test. What should we do?
Call or WhatsApp us. A vent stuck open lets in rain and cold, and can mean the system isn’t ready for a real fire. Common causes are a failed actuator, a fault on the control panel, or a flat backup battery.
Can AOVs be linked to the fire alarm?
Yes, and they often are. The fire alarm or a dedicated smoke detector tells the AOV control panel to open the vents. We can check and test that link as part of a service.
Do you service systems someone else installed?
Yes. We’ll survey the system, record what’s there and how it’s working, and quote for any repairs before taking over the servicing.
Want a price?
Call, WhatsApp or send a quick quote request. We’ll come and have a look, and quotes are free.